The CEC-SLTG-1C form, revised in October 2010, plays a crucial role in ensuring compliance with the California Energy Commission's (CEC) regulations, specifically addressing sign lighting standards in the State of California. Designed to assist in both new sign constructions and alterations, the form comprises essential sections that detail project specifics such as name, address, and whether the sign is indoor or outdoor. It introduces a comprehensive approach to compliance by encompassing mandatory measures for lighting controls, the maximum allowed lighting power, and the use of specific lighting sources. This Certificate of Compliance underscores the importance of adhering to Title 24, Parts 1 and 6 of the California Code of Regulations, focusing on lighting design and energy efficiency. It mandates the certification by responsible parties, declaring under penalty of perjury the truthfulness and correctness of the information provided, responsibility acceptance for the lighting design or construction, and adherence to applicable codes and regulations. Additionally, it covers the installation of lighting controls and power, providing both a declaration and an installation certificate to ensure that all installed features meet the state's rigorous standards for energy efficiency and are consistent with the approved plans and specifications. The form serves as a vital document for project approval and permits application, facilitating coordination and responsibility sharing among different stakeholders involved in sign construction and lighting installations.

QuestionAnswer
Form NameForm Cec Sltg 1C
Form Length4 pages
Fillable?No
Fillable fields0
Avg. time to fill out1 min
Other namestitle 24 sign lighting forms 2019, residential light compliance forms california, compliance certificate lamps online, california lighting certificate

Form Preview Example

STATE OF CALIFORNIA

CERTIFICATE OF COMPLIANCE, SIGN LIGHTING

CEC-SLTG-1C (REVISED 10/10)CALIFORNIA ENERGY COMMISSION

Certificate of Compliance (Sign Lighting)

(Page 1 of 4)

SLTG-1C

Project Name:

 

 

 

Date:

 

 

 

 

 

 

 

 

 

 

 

 

Project Address:

 

 

 

 

 

 

 

 

 

 

 

Location of Sign

† Outdoor Signs

 

† Indoor Signs

 

 

Phase of Sign Construction

† New Signs

 

† Sign Alterations

 

 

Type of Lighting Control

† New Lighting Controls

† Replaced Lighting Controls

† Not Installing Lighting Controls

This Certificate of Compliance includes the following components (check all that apply)

 

 

† Mandatory Measures (Lighting Controls)

† Maximum Allowed Lighting Power

† Specific Lighting Sources

 

 

 

 

 

 

1. Certificate of Compliance Declaration Statement (this may be a C10, C45 or other eligible person)

I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct.

I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting design.

This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24, Parts 1 and 6 of the California Code of Regulations.

The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.

Name:

Signature

Company:

Address:

City/State/Zip:

Phone

License number (may be contractor’s lic #)

Date

2.Installation Certificate (to be signed by responsible person after installation)

 

Permit number

Checked by/Date

 

 

(Enforcement Agency Use )

(Enforcement Agency Use )

 

Installation Declaration statement

I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct.

I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction.

I certify that the installed features, materials, components, or manufactured devices identified on this certificate conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency.

I certify that the requirements detailed on this Certificate of Compliance have been met.

I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the

building owner at occupancy.

Company Name:

Responsible Person's Name:

Responsible Person's Signature:

License number (may be contractor’s lic #)

Date Signed:

Position With Company:

2008 Nonresidential Compliance Forms

October 2010

STATE OF CALIFORNIA

CERTIFICATE OF COMPLIANCE, SIGN LIGHTING

CEC-SLTG-1C (REVISED 10/10)CALIFORNIA ENERGY COMMISSION

Certificate of Compliance (Sign Lighting)

(Page 2 of 4)

SLTG-1C

Project Name:

 

Date:

 

 

 

 

 

3. Mandatory Sign Lighting Controls

NOTES:

1.The same responsible person may install both the sign lighting power and the sign lighting controls, or a different responsible person may install the sign lighting controls than the responsible person installing the sign lighting power.

2.The Mandatory Measures (sign lighting controls) are required for compliance with the sign lighting Standards. If the person responsible for installing the sign lighting power is not also responsible for the sign lighting controls, then the owner of the sign, general contractor, or architect shall be responsible to have the sign lighting controls installed.

3.If more than one person has responsibility for compliance, each responsible person shall prepare and sign a Certificate of Compliance and an Installation Certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement for the entire construction.

3a. Statements of Responsibility: Any person signing the Certificate of Compliance Declaration Statement on page 1 of

4 on this SLTG-1C shall complete Part 3a. Check Yes or No for all of the following statements:

1

I have responsibility for installing the sign lighting controls

† Yes, complete parts 3a and 3b of this form

† No, complete part 3a of this form

2

There are no existing sign lighting controls and I will be installing compliant sign lighting controls

† Yes

† No

3

There are no existing sign lighting controls and someone else will be responsible to install compliant sign lighting controls

† Yes

† No

 

There are existing sign lighting controls that do not comply with the applicable provision of §119 and §133 and I will be

4

installing compliant sign lighting controls

 

 

† Yes

† No

 

There are existing sign lighting controls that do not comply with the applicable provision of §119 and §133 and someone else

5

will be responsible to install compliant sign lighting controls

 

† Yes

† No

3b. Mandatory Sign Lighting Controls

If the person signing the Certificate of Compliance Declaration Statement on page 1 of 4 of this SLTG-1C is responsible for complying with the sign lighting control requirements, that person shall answer all of the following questions:

If there are construction documents, indicate where on the building plans the mandatory measures (sign lighting control) note block can be located:

1

§133(a)1. All indoor sign lighting is controlled with an automatic time switch control that complies with the

Y

 

N

NA

applicable requirements of §119.

†

 

†

†

 

§133(a)1 and 2. All outdoor sign lighting is controlled with an automatic time switch control plus a photo

Y

 

N

NA

2

control, or an outdoor astronomical time switch, that comply with the applicable requirements of §119.

†

 

†

†

Exception to §133(a)2. Outdoor signs in tunnels or large covered areas that require illumination during

Y

 

NA

 

daylight hours.

†

 

†

 

§133(a)3. All outdoor signs are controlled with a dimmer that provides the ability to automatically reduce

Y

 

N

NA

 

sign power by a minimum of 65 percent during nighttime hours.

†

 

†

†

 

Exception 1 to §133(a)3. Signs illuminated for less than one hour per day during daylight hours.

Y

 

NA

 

†

 

†

3

 

 

Exception 2 to §133(a)3. Outdoor signs in tunnels or large covered areas that require illumination during

Y

 

NA

 

daylight hours.

†

 

†

 

Exception 3 to §133(a)3. Only metal halide, high pressure sodium, cold cathode, or neon lamps used for

Y

 

NA

 

illuminating signs or parts of signs.

†

 

†

 

§133(a)4. An Electronic Message Center (EMC) having a new connected lighting power load greater than

Y

 

N

N/A

 

15 kW has a control installed capable of reducing the lighting power by a minimum of 30 percent when

 

 

†

 

†

†

4

receiving a demand response signal that is sent out by the local utility.

 

 

 

 

 

 

Exception to §133(a)4. EMC required by a health or life safety statue, ordinance, or regulation, including

Y

 

NA

 

but not limited to exit signs and traffic signs.

†

 

†

Field Inspector Notes:

2008 Nonresidential Compliance Forms

October 2010

STATE OF CALIFORNIA

CERTIFICATE OF COMPLIANCE, SIGN LIGHTING

CEC-SLTG-1C (REVISED 10/10)

CALIFORNIA ENERGY COMMISSION

 

 

 

Certificate of Compliance (Sign Lighting)

(Page 3 of 4)

SLTG-1C

Project Name:

Date:

4.Maximum Allowed Lighting Power Method of Compliance Certificate of Compliance and Field Inspection Energy Checklist

Complete this part if there are signs using the maximum allowed lighting power method of compliance. (Complete part 5 of this Certificate of Compliance if there are signs using the Specific lighting sources method of compliance)

A

Symbol or Code

B

C

D

E

F

 

G

H

I

 

OPTIONALENERGY– VERIFIED instructions(seelabel below)

AreaSign(ft

Allowed Watts

W/ft2.3=E(

WattsAllowed xD=F

Design

Complies?

 

Internally(I) or Externally(E) Illuminated

AllowedLPD W/ft12=I(

InstalledTotalwatts for sign

ifCompliesH G

 

 

 

 

 

 

 

 

Watts

Y / N

 

 

 

)

 

) )

 

 

 

 

 

 

2

 

2

2

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

Field

Inspector

Check that

Sign

Complies

†

†

†

†

†

†

ASymbol or code used on the plans (when plans are required) and other documents.

BA narrative description of the sign, or location of sign on the building; and the location of sign on construction documents.

OPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory-installed, ENERGY VERIFIED label, confirming that the sign complies with the Section 148 of the California 2008 Title 24, Part 6 Standards, using the Maximum Allowed Lighting Power

 

method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized

C

by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National

Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual

 

inspection program carried out by a Type A Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY

 

VERIFIED label, columns ‘D’ through ‘I’ are not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional

 

method to validate compliance. An ENERGY VERIFIED label is not needed for compliance.

DThe sign area in square feet.

EList “I” if the sign is internally illuminated. List “E” if the sign is externally illuminated.

FAllowed watts per square foot. Enter 12 if the sign is listed as “I” in column E. Enter 2.3 if sign is listed as “E” in column E. G Multiply the square footage in column D times the allowed Lighting Power Density (LPD = watts) in column F.

H Show the total installed watts in the sign, as determined according to the applicable provisions of §130(d or e).

I Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply. J This page doubles as a field inspection checklist.

Field Inspector Notes:

2008 Nonresidential Compliance Forms

October 2010

STATE OF CALIFORNIA

CERTIFICATE OF COMPLIANCE, SIGN LIGHTING

CEC-SLTG-1C (REVISED 10/10)

CALIFORNIA ENERGY COMMISSION

 

 

 

Certificate of Compliance (Sign Lighting)

(Page 4 of 4)

SLTG-1C

Project Name:

Date:

5.Specific Lighting Source Method of Compliance

Certificate of Compliance and Field Inspection Energy Checklist

Complete this part if there are signs using the Specific lighting source method of compliance. (Complete part 4 of this Certificate of Compliance if there are signs using the maximum allowed lighting power method of compliance)

A

Symbol

or

Code

B

C

D

 

E

 

OPTIONAL

 

 

 

 

 

 

 

Field

 

 

ENERGY

Specific light source used for

 

 

 

 

Inspector

 

 

VERIFIED

compliance

 

 

 

 

Check that

 

Description

label

Shall include only lighting

 

 

 

Sign

 

 

(see instructions

technologies listed below

 

 

 

 

Complies

 

 

below)

List all that apply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

†

 

 

†

 

 

†

 

 

 

 

 

 

 

†

 

 

†

 

 

 

 

 

 

 

†

 

 

†

 

 

 

 

 

 

 

 

 

 

 

†

 

 

†

 

 

 

 

 

 

 

†

 

 

 

 

 

 

 

ASymbol or code used on the plans (when plans are required) and other documents.

BA narrative description of the sign, or location of sign on the building; and the location of sign on construction documents

COPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory-installed ENERGY VERIFIED label, confirming that this sign complies with the Section 148 of the California 2008 Title 24, Part 6 Standards, using the Specific Lighting Source Method of Compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, column ‘D’ is not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance.

Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting technologies: List all applicable numbers (1 through 10) that apply in column D above for each row.

 

1

High pressure sodium lamps

 

2

Pulse start or ceramic metal halide lamps served by a ballast with 88% efficiency

3

Pulse start metal halide lamps that are 320 watts, are not 250 watt or 175 watt lamps, and are served by a ballast

with 80% efficiency

 

 

 

4

Neon or cold cathode lamps with transformer or power supply efficiency 75% with rated output current < 50 mA

5

Neon or cold cathode lamps with transformer or power supply efficiency 68% with rated output current 50 mA

D

 

Fluorescent lamps with a minimum color rendering index (CRI) of 80

6

(Note: when using electronic ballasts for compliance, lamps with a CRI < 80 may be used)

 

 

7

Light emitting diodes (LEDs) with a power supply with 80% efficiency

 

 

Single voltage LED external power supplies designed to convert 120 volt AC input into lower voltage DC or AC

8

output, having a nameplate output power less than or equal to 250 watts, and certified to the Energy Commission as

 

 

complying with the applicable requirements of the Appliance Efficiency Regulations (Title 20)

9Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26)

10 Electronic ballasts with a fundamental output frequency 20 kHz

E

This page doubles as a field inspection checklist.

Field Inspector Notes:

2008 Nonresidential Compliance Forms