The HACCP Plan Oyster form represents a critical tool for ensuring the safety and quality of shellfish, specifically oysters, clams, and mussels, throughout their handling and processing. This comprehensive document guides shellstock shippers in Virginia through the meticulous process of monitoring, controlling, and verifying various critical and significant points to prevent health hazards. Key aspects covered in the form include the identification and control of potential contaminants such as pathogens, marine biotoxins, and toxic chemicals through strict receiving, storing, washing, grading, and packing processes. Essential preventive measures, along with specified critical limits and the actions required if these limits are exceeded, are detailed to ensure shellfish safety. Monitoring frequencies, verification procedures, and record-keeping practices are outlined for critical control points (CCPs), including the reception of shellfish from licensed harvesters, ensuring adequate icing or cooling during transport and storage, and the rapid correction of any deviations from set standards. The form requires signatures from company officials, emphasizing the accountability and commitment of the firm to uphold the highest standards of food safety in their shellfish operations.

QuestionAnswer
Form NameHaccp Plan Oyster Form
Form Length3 pages
Fillable?No
Fillable fields0
Avg. time to fill out45 sec
Other namesexamples of a haccp plan, plan shellstock shipper, haccp plan for shellfish, haccp program plan

Form Preview Example

 

 

 

 

 

 

HACCP Plan Form - Shellstock Shipper

 

 

 

VA______SS

Firm Name:

 

 

 

 

 

 

 

Product Type:

 

Oysters, clams and mussels

 

 

 

 

Firm Address:

 

 

 

 

 

 

 

Process Method:

 

Washing, grading and packing of shellstock;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

receiving and storing of shucked and in-shell shellfish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

(2)

 

 

 

 

Monitoring

 

 

(8)

(9)

(10)

(3)

 

 

 

 

 

 

 

 

Critical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Significant

 

 

 

 

 

 

 

 

 

 

Corrective action

Verification

Records

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

Critical Limits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hazards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Point

 

 

for each

(4)

(5)

(6)

 

(7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CCP)

 

 

 

Preventive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure

 

What

How

 

Frequency

Who

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiving

Shellfish may

1) Obtained from

Shellstock tag

Visual check

 

Upon receipt of

Plant personnel

1) and 2) Reject any

Minimum weekly

Shellfish

 

contain

licensed harvester or

and transaction

 

 

each shipment

as assigned

shellfish that are

review of shellfish

receiving

Shellfish

pathogens,

aquaculturist who

record or label

 

 

 

 

 

 

without an identifying

receiving records

record

 

marine biotoxins

has: a) harvested the

 

 

 

 

 

 

 

 

tag, transaction record

and corrective

 

 

 

and toxic

shellstock from

 

 

 

 

 

 

 

 

or label

action records by

Corrective

 

chemicals if

approved waters

 

 

 

 

 

 

 

 

 

 

a HACCP trained

action record

 

received from

and b) Identified the

 

 

 

 

 

 

 

 

3) Shellstock

individual.

 

 

 

growing waters

shellstock with a tag

 

 

 

 

 

 

 

 

temperature is above

 

 

 

 

 

closed to

or transaction record

 

 

 

 

 

 

 

 

50°F internal

 

 

 

 

 

shellfish

2) Receive shellfish

Presence of ice

 

 

 

 

 

 

temperature or

 

 

 

 

 

 

 

 

 

 

 

conveyance

 

 

 

 

 

harvesting.

from a dealer who

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

has identified the

or

 

 

 

 

 

 

temperature is above

Monthly

Thermometer

 

 

 

shellfish with a tag,

 

 

 

 

 

 

 

 

45°F; place under 45°F

calibration of

 

 

 

 

 

 

 

 

 

 

 

calibration

 

 

 

transaction record, or

Conveyance

 

 

 

 

 

 

immediately if the

thermometer

 

 

 

 

 

 

 

 

 

record

 

 

 

label. 3) Shellstock

ambient air

 

 

 

 

 

 

receiving date is the

against NIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

obtained from dealer

temperature

 

 

 

 

 

 

harvest date. If the

certified

 

 

 

 

 

other than the original

or

 

 

 

 

 

 

receiving date is

thermometer or

 

 

 

 

 

harvester shipped

 

 

 

 

 

 

different than the

agitated ice slurry;

 

 

 

 

 

adequately iced; or in

Shellfish

 

 

 

 

 

 

harvest date reject

 

or

 

 

 

 

 

 

 

 

 

 

 

shipment.

 

 

 

 

 

 

a conveyance at or

temperature.

 

 

 

 

 

 

NIST certified

 

 

 

 

 

below 45°F ambient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4) Reject shucked

thermometer with

 

 

 

 

 

air temp; or 50°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shellfish and in-shell

a valid certificate.

 

 

 

 

 

internal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

product not iced or in a

 

 

 

 

 

 

 

or less; or in a

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conveyance at or below

 

 

 

 

 

 

 

conveyance capable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45°F ambient air temp

 

 

 

 

 

 

 

of lowering the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and discontinue use of

 

 

 

 

 

 

 

temperature of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the supplier until

 

 

 

 

 

 

 

shellstock and will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

evidence is obtained

 

 

 

 

 

 

 

maintain it at 50°F or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

that shipping practices

 

 

 

 

 

 

 

less. 4) Shellfish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

have changed.

 

 

 

 

 

 

 

shipped iced, or in a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conveyance at or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

below 45°F ambient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

air temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signature of Company Official:

 

 

 

 

Date:

 

 

 

 

Page # 1

 

 

VER 2/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HACCP Plan Form - Shellstock Shipper

 

VA______SS

Firm Name:

 

 

 

 

 

Product Type:

 

 

Oysters, clams and mussels

 

 

 

 

Firm Address:

 

 

 

Process Method:

 

 

Washing, grading and packing of shellstock;

 

 

 

 

 

 

 

 

 

 

 

 

receiving and storing of shucked and in-shell shellfish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

(2)

 

 

 

Monitoring

 

 

 

 

(8)

(9)

(10)

(3)

 

 

 

 

 

 

 

 

 

 

 

 

Critical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Significant

 

 

 

 

 

 

 

 

Corrective action

Verification

Records

Control

 

 

 

 

 

 

 

 

 

 

Critical Limits

 

 

 

 

 

 

 

 

 

 

 

 

 

Hazards

 

 

 

 

 

 

 

 

 

 

 

 

Point

 

for each

(4)

(5)

(6)

(7)

 

 

 

 

 

 

 

 

 

 

 

 

(CCP)

 

 

Preventive

 

 

 

Frequency

Who

 

 

 

 

 

 

 

 

 

Measure

 

What

How

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shellstock

Growth of

Once under

Time out of

Record duration

For every lot

Plant personnel

If the shellstock are out

Minimum weekly

Shellstock

 

pathogenic

temperature

of time

or pallet.

as assigned.

 

of temperature control

review of shellstock

 

temperature control,

 

temperature control

Points of

bacteria

control.

shellstock

 

 

 

 

transfer/loading

 

 

shellstock not

 

 

outside of

 

 

 

 

for more than 2 hours

transfer records

record

 

 

 

 

 

 

 

 

then check internal

and corrective

dock

 

 

permitted to remain

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature.

action records by a

 

 

 

 

 

outside of

 

 

control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HACCP trained

Thermometer

 

 

 

refrigeration for more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the shellstock

individual.

calibration record

 

 

 

than 2 hours at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature is >50°F,

 

 

 

 

 

 

 

loading dock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the product will be iced

Monthly calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

Corrective action

 

 

 

 

 

 

 

 

 

 

 

or chilled as rapidly as

of thermometer

record

 

 

 

 

 

 

 

 

 

 

 

practicable to bring the

against NIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

internal temperature to

certified

 

 

 

 

 

 

 

 

 

 

 

 

 

50°F.

thermometer or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

agitated ice slurry;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NIST certified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermometer with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valid certificate.

 

 

Signature of Company Official:

 

Date:

 

Page # 2

VER 2/10

 

 

 

 

 

 

HACCP Plan Form - Shellstock Shipper

 

VA______SS

Firm Name:

 

 

 

 

 

Product Type:

 

Oysters, clams and mussels

 

 

 

 

Firm Address:

 

 

 

 

Process Method:

 

Washing, grading and packing of shellstock;

 

 

 

 

 

 

 

 

 

 

 

 

receiving and storing of shucked and in-shell shellfish

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

(2)

 

 

 

Monitoring

 

 

(8)

(9)

(10)

(3)

 

 

 

 

 

 

 

 

 

 

 

Critical

 

 

 

 

 

 

 

 

 

 

 

 

 

Significant

 

 

 

 

 

 

 

Corrective action

Verification

Records

Control

 

 

 

 

 

 

 

Critical Limits

 

 

 

 

 

 

 

 

 

 

 

Point

Hazards

for each

(4)

 

(5)

(6)

(7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CCP)

 

 

Preventive

 

 

 

Frequency

Who

 

 

 

 

 

 

 

 

 

Measure

What

How

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shellfish

Growth of

Shellfish must be:

a) Presence of

a) Visual check

Minimum of

Plant

 

 

Minimum weekly

Shellfish

pathogenic

 

ice; or

for presence of

2 times per

personnel

If ice is not present and the shucked

review of shellfish

storage

storage

 

bacteria

a) Iced; or

 

 

adequate ice; or

day

as assigned

shellfish temperature is between 45°F -

storage area records

temperature

 

 

 

 

 

 

 

b) Shellfish

 

 

 

50°F, the shellfish will be iced or chilled as

and corrective action

record

 

 

 

b) Stored in a

cooler

b) Record

 

 

rapidly as practicable to bring the internal

records by a HACCP

 

 

 

 

 

storage area or

temperature

shellfish cooler

 

 

temperature to 45°F.

trained individual.

Thermometer

 

 

 

conveyance

 

 

temperatures

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

calibration

 

 

 

maintained at 45°F

 

 

 

 

 

If the cooler temperature is >45°F and the

Monthly calibration

 

 

 

(7.2°C) or less

 

 

 

 

 

shellstock temperature is >50°F, the

of thermometer

record

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shellstock will be iced or chilled as rapidly

against NIST

 

 

 

 

 

 

 

 

 

 

 

as practicable to bring the internal

certified

Corrective

 

 

 

 

 

 

 

 

 

temperature to 50°F.

thermometer or

 

 

 

 

 

 

 

 

 

action record

 

 

 

 

 

 

 

 

 

 

 

agitated ice slurry;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

NIST certified

 

 

 

 

 

 

 

 

 

 

 

 

 

thermometer with

 

 

 

 

 

 

 

 

 

 

 

 

 

valid certificate.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signature of Company Official:

 

Date:

 