When starting a construction project, it is important to be familiar with the Wisconsin building permit form. This document lays out all of the requirements for your project and must be filed before work begins. In this post, we will go over what you need to know about the permit form and how to submit it. Stay safe and stay informed with our blog!

QuestionAnswer
Form NameWisconsin Building Permit Form
Form Length3 pages
Fillable?No
Fillable fields0
Avg. time to fill out45 sec
Other nameswi_un_building_ per_ap wisconsin building permit formpdffillercom 2008

Form Preview Example

 

Dept of Safety & Professional

 

 

 

 

Wisconsin Uniform Building

 

 

Application No.

 

 

 

 

Services

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Permit Application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industry Services Division

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wisconsin Stats. 101.63, 101.73

 

Instructions on back of second ply. The information you provide may be

Parcel No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used by other government agency programs [(Privacy Law, s. 15.04 (1)(m)]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERMIT REQUESTED

 

 

Constr.

HVAC

Electric

Plumbing

Erosion Control

 

Other:

 

Owner’s Name

 

 

 

 

 

 

 

 

 

Mailing Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contractor Name & Type

 

 

 

 

Lic/Cert#

Exp Date

 

 

Mailing Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Telephone & Email

 

Dwelling Contractor (Constr.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dwelling Contr. Qualifier (The Dwelling Contr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Qualifier shall be an owner, CEO, COB or employee of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dwelling Contr.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Contractor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Master Electrician

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plumbing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROJECT

 

Lot area

 

One acre or more

 

 

 

Town

Village

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCATION

 

 

 

 

Sq.ft.

 

of soil will be

 

 

 

 

City of

 

 

 

 

 

 

 

1/4,

 

 

 

1/4, of Section

 

, T

 

N, R

 

E/W

 

 

 

 

 

 

 

 

disturbed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Building Address

 

 

 

 

 

 

 

 

County

 

 

 

 

 

 

 

 

 

 

 

Subdivision Name

 

 

 

 

 

 

 

 

Lot No.

 

Block No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zoning District(s)

 

 

 

 

 

 

Zoning Permit No.

 

 

 

 

 

 

 

Setbacks:

 

Front

 

 

 

 

 

Rear

 

 

 

 

Left

 

 

 

Right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ft.

 

 

 

ft.

 

 

 

 

 

 

ft.

 

 

 

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. PROJECT

 

 

 

 

 

 

 

3. OCCUPANCY

 

6. ELECTRIC

 

 

9. HVAC EQUIP.

 

 

12. ENERGY SOURCE

 

 

 

 

 

 

 

 

 

 

 

New

Repair

 

Single Family

 

Entrance Panel

 

 

 

Furnace

 

 

 

 

 

Fuel

 

Nat

 

 

LP

 

 

Oil

Elec

 

Solid

Solar

 

Alteration

Raze

 

Two Family

 

Amps:

 

 

 

Radiant Basebd

 

 

 

 

 

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

Geo

 

Addition

Move

 

Garage

 

 

Underground

 

 

Heat Pump

 

Space Htg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other:

 

 

 

 

 

 

Other:

 

 

Overhead

 

 

 

Boiler

 

 

 

 

Water Htg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.WALLS

 

 

 

Central AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. AREA INVOLVED (sq ft)

 

 

4. CONST. TYPE

 

 

Wood Frame

 

 

Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit 1

Unit 2

Total

 

Site-Built

 

 

Steel

 

 

 

Other:

 

 

 

 

13. HEAT LOSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unfin.

 

 

 

 

 

 

 

 

Mfd. per WI UDC

 

 

ICF

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU/HR Total Calculated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bsmt

 

 

 

 

 

 

 

Mfd. per US

 

 

Timber/Pole

 

10. SEWER

 

 

Envelope and Infiltration Losses (available from "Total

Living

 

 

 

 

 

 

 

 

HUD

 

 

Other:

 

 

 

Municipal

 

Building Heating Load" on Rescheck report)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Area

 

 

 

 

 

 

 

5. STORIES

 

8. USE

 

 

 

Sanitary Permit#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Garage

 

 

 

 

 

 

 

 

1-Story

 

 

Seasonal

 

 

 

 

 

 

 

 

 

 

 

14. EST. BUILDING COST w/o LAND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deck/

 

 

 

 

 

 

 

2-Story

 

 

Permanent

 

 

11. WATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Porch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other:

 

 

Other:

 

 

 

Municipal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Totals

 

 

 

 

 

 

 

Basement

 

 

 

 

 

 

 

 

 

 

On-Site Well

$

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I understand that I: am subject to all applicable codes, laws, statutes and ordinances, including those described on the reverse side of the last ply of this form; am subject to any conditions of this permit; understand that the issuance of this permit creates no legal liability, express or implied, on the state or municipality; and certify that all the above information is accurate. If one acre or more of soil will be disturbed, I understand that this project is subject to ch. NR 151 regarding additional erosion control and stormwater management and the owner shall sign the statement on the back of the permit if not signing below. I expressly grant the building inspector, or the inspector's authorized agent, permission to enter the premises for which this permit is sought at all reasonable hours and for any proper purpose to inspect the work which is being done.

I vouch that I am or will be an owner occupant of this dwelling for which I am applying for an erosion control or construction permit without a Dwelling Contractor Certification and have read the cautionary statement regarding contractor responsibility on the second page of this form.

 

APPLICANT (Print:) __________________________ Sign:_____________________________

DATE ________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROVAL CONDITIONS

This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this

 

permit or other penalty.

 

See attached for conditions of approval.

 

 

 

 

 

 

 

 

 

 

 

ISSUING

 

 

Town of

 

 

County of

 

 

 

 

 

State-Contracted Inspection

Municipality Number of Dwelling Location

 

JURISDICTION

 

Village of

 

 

State

 

 

 

 

 

 

Agency#:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

City of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEES:

 

 

 

 

 

PERMIT(S) ISSUED

WIS PERMIT SEAL #

 

 

PERMIT ISSUED BY:

 

 

Plan Review

$

 

 

 

 

Construction

 

 

 

 

 

 

 

Name ____________________________________

 

Inspection

$

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HVAC

 

 

__________________

 

 

Date ____________ Tel. _____________________

 

Wis. Permit Seal

$

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cert No. __________________________________

 

Other

$

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

Total

$

 

 

 

 

Plumbing

 

 

 

 

 

 

 

 

Email: ____________________________________

 

 

 

 

 

Erosion Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SBD-5823(R08/17) Distribute: Ply 1 Issuing Jurisdiction;

Ply 2- Issuer forwards to state w/in 30 days;

Ply 3- Inspector; Ply 4- Applicant

INSTRUCTIONS

The owner, builder or agents shall complete the application form down through the Signature of Applicant block and submit it and building plans and specifications to the enforcing jurisdiction, which is usually your municipality or county. Permit application data is used for statewide statistical gathering on new one- and two-family dwellings, as well as for local code administration. Please type or use ink and press firmly with multi-ply form.

PERMIT REQUESTED

Check off type of Permit Requested, such as structural, HVAC, Electrical or Plumbing.

Fill in owner's current Mailing Address and Telephone Number.

If the project will disturb one acre or more of soil, the project is subject to the additional erosion control and stormwater provisions of ch. NR 151 of the WI Administrative Code. Checking this box will satisfy the related notification requirements of ch. NR 216.

Fill in Contractor and Contractor Qualifier Information. Per s. 101.654 (1) WI Stats., an individual taking out an erosion control or construction permit shall enter his or her dwelling contractor certificate number, and name and certificate number of the dwelling contractor qualifier employed by the contactor, unless they reside or will reside in the dwelling. Per s. 101.63 (7) Wis. Stats., the master plumber name and license number must be entered before issuing a plumbing permit.

PROJECT LOCATION

Fill in Building Address (number and street or sufficient information so that the building inspector can locate the site.

Local zoning, land use and flood plain requirements must be satisfied before a building permit can be issued. County approval may be necessary.

Fill in Zoning District, lot area and required building setbacks.

PROJECT DATA - Fill in all numbered project data blocks (1-14) with the required information. All data blocks must be filled in, including the following:

2. Area (involved in project):

Basements - include unfinished area only

Living area - include any finished area including finished areas in basements Two-family dwellings - include separate and total combined areas

3.Occupancy - Check only "Single-Family" or "Two-Family" if that is what is being worked on. In other words, do not check either of these two blocks if only a new detached garage is being built, even if it serves a one or two family dwelling. Instead, check "Garage" and number of stalls. If the project is a community based residential facility serving 3

to 8 residents, it is considered a single-family dwelling.

9. HVAC Equipment - Check only the major source of heat, plus central air conditioning if present. Only check "Radiant Baseboard" if there is no central source of heat.

10.Sewage - Indicate if the dwelling will be served by municipal sewer or privately owned treatment system. If a private system is used, include the Sanitary Permit number. Note: A building permit cannot be issued for a new dwelling that utilizes a privately owned wastewater treatment system until a sanitary permit has been issued. This applies to any new or existing private onsite wastewater treatment system that will be used by the dwelling.

13.Heat Loss Provide heat loss summation data (BTUs/HR) derived from the ResCheck report or the “Heating System Sizing Summary Calculator” available on the Division’s website: http://dsps.wi.gov/Programs/Industry-Services/Industry- Services-Programs/One-and-Two-Family-UDC.

14.Estimated Cost - Include the total cost of construction, including materials and market rate labor, but not the cost of land or landscaping.

SIGNATURE The owner or the contractor’s authorized agent shall sign and date this application form. If you do not possess the Dwelling Contractor certification, then you will need to check the owner-occupancy statement for any erosion control or construction permits.

CONDITIONS OF APPROVAL - The authority having jurisdiction uses this section to state any conditions that must be complied with pursuant to issuing the building permit.

ISSUING JURISDICTION: This must be completed by the authority having jurisdiction.

Check off Jurisdiction Status, such as town, village, city, county or state and fill in Municipality Name

Fill in State Inspection Agency number only if working under state inspection jurisdiction.

Fill in Municipality Number of Dwelling Location

Check off type of Permit Issued, such as construction, HVAC, electrical or plumbing.

Fill in Wisconsin Uniform Permit Seal Number, if project is a new one- or two-family dwelling.

Fill in Name and Inspector Certification Number of person reviewing building plans and date building permit issued.

(Part of Ply 4 for Applicants)

Cautionary Statement to Owners Obtaining Building Permits

101.65(lr) of the Wisconsin Statutes requires municipalities that enforce the Uniform Dwelling Code to provide an owner who applies for a building permit with a statement advising the owner that:

If the owner hires a contractor to perform work under the building permit and the contractor is not bonded or insured as required under s. 101.654 (2) (a), the following consequences might occur:

(a)The owner may be held liable for any bodily injury to or death of others or for any damage to the property of others that arises out of the work performed under the building permit or that is caused by any negligence by the contractor that occurs in connection with the work performed under the building permit.

(b)The owner may not be able to collect from the contractor damages for any loss sustained by the owner because of a violation by the contractor of the one- and two- family dwelling code or an ordinance enacted under sub. (1) (a), because of any bodily injury to or death of others or damage to the property of others that arises out of the work performed under the building permit or because of any bodily injury to or death of others or damage to the property of others that is caused by any negligence by the contractor that occurs in connection with the work performed under the building permit.

Cautionary Statement to Contractors for Projects Involving Building Built Before 1978

If this project is in a dwelling or child-occupied facility, built before 1978, and disturbs 6 sq. ft. or more of paint per room, 20 sq. ft. or more of exterior paint, or involves windows, then the requirements of ch.

DHS 163 requiring Lead-Safe Renovation Training and Certification apply. Call (608)261-6876 or go to the Wisconsin Department of Health Services’ lead homepage for details of how to be in compliance.

Wetlands Notice to Permit Applicants

You are responsible for complying with state and federal laws concerning the construction near or on wetlands, lakes, and streams. Wetlands that are not associated with open water can be difficult to identify. Failure to comply may result in removal or modification of construction that violates the law or other penalties or costs. For more information, visit the Department of Natural Resources wetlands identification web page or contact a Department of Natural Resources service center.

Additional Responsibilities for Owners of Projects Disturbing One or More Acre of Soil

I understand that this project is subject to ch. NR 151 regarding additional erosion control and stormwater management standards, and will comply with those standards.

Owner's Signature: _______________________________________ Date: __________________

How to Edit Wisconsin Building Permit Form Online for Free

With the help of the online PDF tool by FormsPal, you may fill in or change Wisconsin Building Permit Form here and now. Our tool is consistently evolving to provide the best user experience achievable, and that's because of our commitment to continual improvement and listening closely to feedback from customers. With a few easy steps, you are able to start your PDF journey:

Step 1: Simply click the "Get Form Button" at the top of this page to get into our pdf editor. This way, you'll find all that is required to work with your document.

Step 2: This editor allows you to change PDF forms in various ways. Enhance it with your own text, adjust original content, and add a signature - all close at hand!

Concentrate when completing this pdf. Make sure every blank field is filled out properly.

1. To start with, while filling out the Wisconsin Building Permit Form, beging with the area that contains the following blank fields:

Wisconsin Building Permit Form writing process clarified (portion 1)

2. Once this part is done, it's time to include the necessary specifics in Zoning Permit No OCCUPANCY Single, CONST TYPE, Subdivision Name Front, Rear, Left, Block No Right, Setbacks, ELECTRIC Entrance Panel Amps, Underground Overhead, WALLS, Wood Frame, Steel, ICF, HVAC EQUIP, and ENERGY SOURCE in order to move forward further.

Part no. 2 in filling out Wisconsin Building Permit Form

3. This next segment is all about APPROVAL CONDITIONS, ISSUING JURISDICTION, Town of, Village of, City of, This permit is issued pursuant to, See attached for conditions of, County of, State, StateContracted Inspection Agency, Municipality Number of Dwelling, PERMITS ISSUED WIS PERMIT SEAL, PERMIT ISSUED BY, FEES Plan Review Inspection Wis, and SBDR Distribute - fill in all of these fields.

Filling in segment 3 in Wisconsin Building Permit Form

4. This particular part arrives with the following empty form fields to consider: I understand that this project is.

Ways to prepare Wisconsin Building Permit Form portion 4

People often make mistakes while filling in I understand that this project is in this section. Be certain to reread whatever you enter right here.

Step 3: After you've glanced through the details you given, press "Done" to complete your document generation. Try a free trial subscription at FormsPal and obtain immediate access to Wisconsin Building Permit Form - which you may then use as you would like in your FormsPal account. FormsPal guarantees your information privacy with a secure method that in no way saves or shares any personal data typed in. Be confident knowing your documents are kept safe when you work with our editor!