DD Form 2026 at a glance
What it is: The Oil Analysis Request Form, DD Form 2026 (AUG 2024), is used for submission of routine or special oil samples.
Who signs: If visual inspection of MCD is required, the person conducting the inspection must sign the MCD Point of Contact (POC) signature block (not OAP lab personnel).
A filled-in DD Form 2026 example: an initial oil sample from a ship

How to fill out DD Form 2026, box by box
To oil analysis laboratory
Operating activity name, address and UIC
POC and maintenance supervisor

Enter the name and rank of the person submitting the sample.
Enter the phone number and email address of the person submitting the sample.
Enter the name and email address of the Maintenance Supervisor responsible for the submitted sample. For Navy, enter information for the Maintenance Material Control Officer (MMCO) or other responsible individual.
Component and end item

Enter the designation or description of the component or equipment being sampled. For engines, include the type, model, and series.
Enter complete serial number of the component or equipment being sampled.
If applicable, enter position or position number of the component. This is common for engines and some gearboxes.
Enter mission, design and series (type, model, series) of end item which contains the component or system being sampled. This is often an aircraft or vehicle.
Enter the complete end item serial number (aircraft bureau number).
Date and time sample taken and engine shutdown time
Hours / miles since new, overhaul and oil change

Enter the total hours/miles since new of the component being sampled to the nearest whole hour/mile (round up at 0.5). Indicate if the number reported is in hours or miles.
Enter the total hours/miles since overhaul of the component being sampled to the nearest whole hour/mile (round up at 0.5). If the equipment has never been overhauled, the total operating hours/miles since new are reported.
Air Force personnel will normally enter total flying hours.
For Navy ship equipment enter hours if known, otherwise leave blank.
Enter hours/miles since oil change on the component being sampled to the nearest whole hour/mile (round up at 0.5).
If available, enter the miles or hours of the aircraft or vehicle upon which the component is installed. This is equivalent to the odometer reading. Specify if hours or miles are reported.
Reason for sample

Enter reason for taking sample. Mark applicable block; if "Other" block is marked, specify reason for sample, e.g., initial sample, warning light, etc. NOTE Oil consumption information is essential to the evaluation process for trend analysis and to determine if a system is using excessive amounts of oil.
If the sample is a special sample, it must be prominently marked in red (such as red borders), both on the form and on the outside of the mailing container to alert the laboratory to the need for immediate processing.
Report suspected excessive oil usage to both the local system manager(s) and the local oil analysis laboratory.
Enter the quantity of oil added since the last sample and specify the measurement used.
How taken, sample temperature and oil type
Remarks
Magnetic chip detector (MCD) visual inspection of debris
Submitting activity sample number
For laboratory use only

The For Laboratory Use Only section of the form is completed by the laboratory personnel performing the analysis of the oil sample. It is rarely used since most oil analyses are automated and use computer systems to record results and provide results back to customers.
Check the appropriate block for the elemental / wear metal instrument used, i.e. "SPECTROMETER" or "FL-58". Fill in all values obtained for each element as indicated by the instrument.
Fill in the results for the tests performed.
Fill in the results along with the Overall Class and/or Overall ISO Code, if performed.
Enter the appropriate recommendation code based upon the oil analysis test results.
Provide any additional information appropriate based on the results obtained.
More rules for DD Form 2026
Customers shall use only plain language, unless otherwise directed.
If extra space is required, attach additional sheets.
This form must accompany the sample. Do not apply adhesives or tape to this form.
If your situation is different
The form reports chip detector inspection results
Reporting Chip Detector Inspection Results.
Automated reporting systems are not available
Documenting / Reporting Analysis Results when automated reporting systems are not available.
The oil analysis servicing of a component is transitioned to another laboratory
The Transient Aircraft Oil Analysis Record section of the form is on the back side. It is used in the uncommon situation where the oil analysis servicing of a specific component is being transitioned from one oil analysis laboratory to another and the losing laboratory is not equipped with an automated data system.
Sources